Plug & Play EN 806 (Plumbing) / IEC 60364 (Electrical) / EN 12828

Plug-and-Play MEP Corridors & Factory Testing

Factory-installed and pressure-tested plumbing, pre-wired electrical quick-couplings and radiant underfloor heating pre-commissioned before departure.

Technical Subsystem Keywords: # plug and play MEP systems # factory pressure tested plumbing # pre-wired electrical couplings # underfloor heating manifolds

Key Engineering & Performance Metrics

Pressure Test Hydrostatic pressure test at 6 bar for 24 hours
Electrical Safety IEC 60364 insulation & continuity testing
Heating Cooling Integrated hydronic underfloor + VRF / Heat Pump prep
Ventilation Decentralized or central MVHR with heat recovery ≥ 85%
Structural Mechanics

System Architecture & Structural Mechanics

Mechanical, electrical and plumbing (MEP) installations represent over 80% of on-site defect risks in traditional construction. By routing all supply lines, drain stacks and wiring inside dedicated accessible module chases in the factory, SERMODULA transfers complex trade coordination into an engineered manufacturing protocol.
Norm Compliance

Technical Standards & Compliance Matrix

Verified design standards, testing criteria and tolerance controls.

Technical Parameter #1

Structural & Seismic

Applicable Standard
Eurocode 3 (EN 1993) & Eurocode 8 (EN 1998)
Limit / Rating
S355JR / S275JR, DCM/DCH Ductility
Verification Method
3D FEM Analysis & Verification Report
Technical Parameter #2

Steel Fabrication & Welding

Applicable Standard
EN 1090-2 (EXC3) / ISO 3834-2
Limit / Rating
EXC3 Execution Class, CE Marked
Verification Method
NDT Ultrasonic & Magnetic Testing
Technical Parameter #3

Corrosion Protection

Applicable Standard
ISO 12944 (C3 / C4 Dayanım)
Limit / Rating
Epoxy Primer + PU Topcoat (160–240 µm)
Verification Method
DFT Gauge & Cross-Cut Adhesion
Technical Parameter #4

Fire & Acoustic Separation

Applicable Standard
EN 13501-2 / ISO 717-1
Limit / Rating
REI 60–120 · Rw ≥ 56 dB / Ln,w ≤ 48 dB
Verification Method
Accredited Lab Test Certification
Technical Parameter #5

Dimensional Tolerances

Applicable Standard
EN 1090-2 D Sınıfı & ISO 2768
Limit / Rating
Diagonal & Vertical max. ±2.0 mm
Verification Method
3D Laser Metrology & Calibration Jig
Factory Production

Factory Pre-fabrication & Quality Verification (ITP)

Vertical risers connect at floor level via push-fit expansion couplings and standardized multi-pin electrical harness connectors (Wieland/WAGO), reducing on-site trade time to hours.
Interface Discipline

Layer Architecture & On-site Interface

01

Structural Node & Joint

Cast-steel corner blocks and EN 14399 grade 10.9 high-strength structural bolts guarantee instant load transfer.

02

Acoustic & Fire Seals

Continuous EPDM weather seals, intumescent fire gaskets and elastomeric vibration isolators installed between volumetric cells.

03

Vertical Shaft Coupling

Vertical MEP risers align on precision axes with flexible compensator couplings for rapid single-point hookup.

04

Certified Crane Rigging

Integrated rigging pick-points calibrated to volumetric center of gravity ensure balanced, tilt-free crane erection.

Technology Ecosystem

Explore Other Engineering Subsystems

Coordinated building envelope, MEP, acoustic, connection and quality control engineering systems.

Direct Architectural & Engineering Leadership

Structure Your Technical Specification & Engineering Baseline

Share your structural parameters, Eurocode design requirements and target typology for a verified engineering feasibility review with the SERMODULA Engineering & Technical Team.

SERMODULA Structural Engineering Desk Eurocode 3 & 8 / EN 1090-2 Technical Coordination
Direct (GSM): +90 (505) 507 04 18
Central Switchboard: +90 (216) 614 04 34
Engineering Email: [email protected]
Knowledge Base

Frequently Asked Questions

How are modules connected to municipal utilities?
Each building has a central basement/ground interface where internal risers meet local municipal water, sewer, and grid electricity meters.
Can heat pumps be integrated?
Yes. All piping is sized for low-temperature heat pump operation with pre-installed underfloor heating circuits and expansion tanks.
How is water leakage prevented during shipping?
Lines are drained, pressurized with dry compressed air, and monitored with gauges during transit to confirm zero leakage upon site arrival.
What electrical voltage standards are supported?
Wiring conforms to 230V/400V 50Hz for Europe, UK and International markets with certified RCD and MCB consumer units.
Are sanitary fixtures factory-installed?
Yes. Toilets, vanities, walk-in showers, and faucets are fully installed, sealed, and protected under protective film before export.